Description

The Medisys Neocare Neonatal Ventilator is a medical device designed for newborn babies requiring respiratory support. It is a compact, advanced machine that provides controlled airflow to the baby’s lungs, allowing healthcare professionals to customize ventilation parameters based on the newborn’s specific needs. The Medisys Neocare Neonatal Ventilator uses an endotracheal tube to deliver a mixture of air and oxygen, ensuring proper lungs inflated. The ventilator has sensors and monitors that continuously monitor breathing patterns, oxygen levels, and vital signs, adjusting airflow and pressure as needed. It also features alarms and safety features to alert healthcare providers of any changes or issues. The Neocare Neonatal Ventilator is essential in neonatal intensive care units (NICUs) and other specialized medical facilities, helping vulnerable infants breathe and providing support until they can independently do so.

Key Features of Medisys Neocare Neonatal Ventilator:

  • Large LCD display
  • Both volume & pressure limiting
  • Apnea backup ventilation
  • Pressure control ventilation
  • Servo controlled FiO2
  • Monitoring of patient data
  • Both flow and pressure triggering
  • Automatic calibration of Oxygen sensor
  • Alarm Log

Neocare Neonatal Ventilator for neonatal, child and pediatric patients is a microprocessor regulated and pneumatically operated ventilator. To reduce the possibilities of Volume Trauma or Barotrauma, both volume and pressure limiting features have been added. The system also includes joint flow and pressure triggering and sensing is performed at the patient’s proximal.

Specification of Medisys Neocare Neonatal Ventilator:

Product Name Medisys Neocare Neonatal Ventilator
Brand Medisys
Flow 2-25 litre per minute
PCV 0 to 40 cmH2O
Alarms High / Low inspiratory pressure, High/Low Tidal Vol, High/Low FiO2, loss of inlet gas, Apnea & elect
Alarm mute 30 seconds
Safety Pressure Relief 15 to 50 cmH2O
Display Large 12.1 inches graphical LCD
Tidal Volume 6 to 300 ml
Modes of operation AC, SIMV/IMV, CPAP with backup ventilation and Standby
Inspiratory time 0. 2 to 3. 0 seconds
I : E ratio 1:1 to 1 : 10 (AC ) 1:1 to 1 : 60 ( SIMV ); Inverse 1:1 to 4 : 1
Frequency 1 to 150 breaths per minute
Triggering Flow triggering (1-10 lpm ) & Pressure Triggering (0.5 – 8 cmH2O )
Expiratory pressure 0 to 20 cmH2O
Inspiratory pressure limit 5 to 50 cmH2O
Power Supply 220-240 V AC
Dimensions 28 x 32 x 32 cm
Weight 8.2